IT600 serise power supply have four standard communication
interfaces:RS232,USB,GPIB,RS485. The customer can choose any one according to his
demands.
4.1 RS232 Interface
Using a cable with two COM ports to connect power supply and PC.Then please press
+ (Menu) button to enter the menu to configure the communication
parameters.You could do the secondary development with all SCPI commands.
Note
The setup about RS232 in the program should agree with the configuration in the system set.If you want
to change the communication parameters,please press + (Menu) button to enter the
system set.
RS-232 Data style
RS232 is a 10-bit data with start bit and stop bit.The start bit and stop bit can not be
edited.While you could select the odd parity or even parity under the system set.
Odd or EVEN options have been saved in the nonvolatile memory.
Baudrate
Edit baudrate:press + (Menu) to enter the menu setup,you could select the
baudrate among the following options:
4800 9600 19200 38400 57600 115200
RS-232 connection
Please use a straight-through RS232 cable with DB-9 interface and connect the RS232
serial port with the controller’s serial port(for example.PC). Form 2-2 give a detailed
description for each pin.
RS-232 pins description