Warm weather (above +5ºC):
If the indoor temperature is too low or too high during
warm weather, you use fine tuning to change it. You come
to Temp. Fine Tuning by pressing “Heat” and turning the
dial to the right.
Fine tuning can be set in areas –10°C to 10°C. You change
the fine tuning in the same way as “Temp. increase/de-
crease” as described on the previous page.
The heat curve can also be fine tuned. You do this in the “Temp. fine tune” display. The dotted line
illustrates how the parallel offset has been turned towards plus. The entire curve moves upwards, in
contrast to increasing the slope, when only the slope changes.
The dotted line illustrates
how the fine tuning adjust-
ment has been turned
towards plus.
Fine tuning adjustment
Radiator return
temperature
Outdoor temperature
Rego600 K1
020301 12:00:00 Fr
Heat Info Menu
Temp. fine-tune.
-10° 0,0° 10°
Return Adjust