TrimmingtheUpperandLowerBafes
Toimproveuedrawandsmokedischargethelowerandupperbafesmaybetrimmedbackeachend.Allow
theappliancetocool.Removethelowerandupperbafesasdescribedintheappliancepreparationsection.
Theupperbafemaybetrimmedbackby15mmto25mmeachendandeachlowerboardbafetrimmedback
10mmto15mmfromtheirouteredges.Trimmingcanbecarriedoutusingnormalwoodcuttinghandtools.Ret
thebafesandretest.Thisisnotasolutiontoovercomepoorchimneydesign.Ifafterfurtherretestingthis
cannot be resolved then further investigation will be required or seek expert advice. Advise the customer not to
usethereuntilexpertadvicehasbeensought.
Trimmingthelowerbafessidesandfrontedges
Upperbafeboard Trimmingtheupperbafe
Notice Plate
Ensure that any notice plate is provided in line with the building regulations J4. The notice should contain
informationontheperformancecharacteristicsofthehearth,replace,ueorchimneyandistobexedinan
appropriate place.
Carbon Monoxide (CO) Alarm
Fit a carbon monoxide (CO) alarm in the room where the appliance is located. Adhere to local regulations and
the manufacturers instructions when siting the detector position.
Cleaning Up
Immediatelyafterinstallation,thevisiblepartsofthereshouldbecleanedup.Thereafter,thesurfacesmaybe
kept clean by using a light brush to remove dust and by occasional wiping with a lint-free cloth.
Lighting after installation
The Jetmaster should not be run hard until any surrounding cement and plasterwork is completely dry and
cured.
A. 7 days drying time if the house has other forms of heating.
B. Atleast14daysiftheinstallationisinaneworunoccupiedproperty,oristtedintoacompletelynew
chimney breast.