Servicing Instructions
IMPORTANT –
ALLOW THE FIRE TO COOL BEFORE COMMENCING SERVICING OR CLEANING
The data can be found on the data badge located at the rear of the stove.
Servicing
To ensure safe, efcient operation of the appliance, it is necessary to carry out routine servicing at regular
intervals.
The frequency of servicing will depend on the particular installation conditions and the frequency of use.
Chimney Sweeping
We recommend that chimneys should be swept at least once a year during the burning season. More frequent
sweepingmaybenecessarywhereresareburnedthroughouttheyearorwherelowgradewoodsareused
asfuels.Thechimneycanbesweptthroughthere.Thereisprovidedwithremovabletertiaryairtubesand
bafestofacilitatechimneysweepingandfortheremovalofsootfromtheunit.Iftheuehaspreviouslybeen
usedwithanopenrethenitshouldbesweptaftertherstmonthofusingitwiththestovetted.Thiswillclear
anyloosesootdepositsfromprevious“open”reburning.SeeServicingInstructions.
Besideschimneysweepinganyinternaluewaysshouldalsobecleaned.
Ensurethatanysootthathasfallenontothetopofthebafesisremoved.
Ensure that any soot that has accumulated around the tertiary air tube holes is removed.
Remove and clean the tertiary air tubes and the board bafes. Replace and ensure correct operation and
adjustment.
Safety Checks
Acheckonthesealbetweenthereandtheueshouldbecarriedout.
A check on the seal of the door should be carried out.
Checkthattheheatshieldisttedcorrectly.
Check condition of glass door.
Check the air supply requirements.
Checkifacarbonmonoxidealarmhasbeenttedintotheroomwherethereisoperating.
Smoke Draw Test
Finally carry out a smoke draw test as described in Commissioning Section or to the HETAS recommended
requirements.
Before any maintenance work or sweeping is carried out always remove the door and store safely.
DoorRemovalandRetting
Unlock the door with the handle provided.
Remove the door as detailed in section on appliance preparation.
Log Retainer Removal
The log retainer can be removed from the front of the stove by sliding upwards between the slots at each side
at the front.