Installation Data Table
DIMENSIONS
MODEL
WIDTH
HEIGHT (Small Legs)
HEIGHT (Large Legs)
DEPTH
WEIGHT
OUTPUTS /
TEMPERATURES WOOD
ROOM SIZE HEATED
TOTAL NOMINAL HEAT
OUTPUT WOOD WHEN
TESTED TO EN13240: 2001
NET EFFICIENCY WOOD
TO EN13240: 2001
FLUE GAS TEMPERATURE
TO EN13240: 2001
FLUE GAS MASS FLOW TO
EN13240: 2001
MEAN CO2 IN FLUE GAS
TO EN13240: 2001
MEAN CO @ 13% O2 TO
EN13240: 2001
FLUE SIZE
MINIMUM FLUE SIZE
DIAMETER
MINIMUM FLUE AREA
MINIMUM FLUE DRAUGHT
CHIMNEY HEIGHT
ABOVE FIRE
AIR SUPPLY
AREA
MAXIMUM WOOD SIZE
Length & Diameter
MAXIMUM REFUEL WEIGHT
MINIMUM REFUEL
INTERVAL
mm
ins
mm
ins
mm
ins
mm
ins
Kg
M³
kW
%
°C
gs-1
%
%
mm
in
cm
2
in
2
Pa
M
ft
cm
2
in
2
mm
Kg
Min
18f
426
16
3
/
4
650
25
5
/
8
700
27
1
/
2
380
15
55
100
4.9
84
227
3.5
11.65
0.30
125
5
123
20
12
4.5
15
0*
0*
300 Lth
Ø75
1.28
60
60f
608
24
650
25
5
/
8
700
27
1
/
2
380
15
-
150
7.5
80
-
-
-
-
150
6
177
28
12
4.5
15
14
2.5
450 Lth
Ø100
2.25
60
5
MODEL 18f 60f
* An air supply may be required in homes which have high levels of
air-tightness
Jetmasterestimatedgures
426mm (608mm)
DIMENSIONS IN BOLD ARE FOR 18f DIMENSIONS IN BRACKETS ARE FOR 60f
380mm (380mm)
355mm (355mm)
15mm (15mm)
134mm (134mm)
109mm (109mm)
130mm (150mm) Internal diameter
213mm (304mm)
10mm
(10mm)
45mm
(45mm)
500mm
(540mm)
105mm
(105mm)
SHORT LEG SHOWN 105mm (105mm)
LONG LEG NOT SHOWN 155mm (155mm)
DOOR LOCK
FLUE SPIGOT
AIR CONTROL LEVER
AIR SUPPLY PIPE
63mm (63mm)
HEAT SHIELD

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jetmaster 18f and is the answer not in the manual?

Jetmaster 18f Specifications

General IconGeneral
BrandJetmaster
Model18f
CategoryStove
LanguageEnglish

Related product manuals