22. RESETTING THE SAFETY CLUTCH (DNU-1541S)
The safety clutch functions when an excessive load is applied to the hook or the other components during sewing. At this
time, the hook will never rotate even if turning the handwheel. When the safety clutch has functioned, remove the cause
and reset the safety clutch as given in the following procedure.
1) Pressing push button
located on the top surface of the machine bed, strongly turn the handwheel in the reverse
direction of rotation.
2) The resetting procedure completes when the handwheel clicks.
WARNING :
To protect against possible personal injury due to abrupt start of the machine, be sure to start the follow-
ing work after turning the power off and ascertaining that the motor is at rest.
– 43 –

Other manuals for JUKI DNU-1541S

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the JUKI DNU-1541S and is the answer not in the manual?

JUKI DNU-1541S Specifications

General IconGeneral
Machine TypeSingle Needle Lockstitch
Max Stitch Length9 mm
Presser Foot Lift by Hand9 mm
Presser Foot Lift by Knee16 mm
LubricationAutomatic
Max Sewing Speed2500 stitches per minute
HookFull Rotary Hook
Bed Size477mm(L)×177mm(W)