– 14 –
6-2 Adjusting the needle entry point
○
Remove the face cover.
Adjustmentprocedure
1.Selectthestraightstitchusingthepatternselectingbutton.Choosecenterneedleposition.
2.Assembleaneedle#14intotheneedlebar,loosenthesetscrewintheeccentriccollarandadjustthefeed
bareccentriccollarsothattheneedlemeetsthecenteroftheneedleslotinthethroatplatewhenitreach-
esthetopsurfaceofthethroatplatebyturningthehandwheel.
6-3 Feed dog height
○
Do not remove the throat plate.
Adjustmentprocedure
1. Set the amount of feed to 0 (zero).
2.Turnthehandwheeltobringthefeeddogtoitshighestdeadpoint.
3.Turnleftsideshaftaandrightsideshaftbwitha2mmhexagonalwrench.
4.Adjustthefeeddogheightsothatthefrontandrearendsofthefeeddogarespaced1.0±0.1mmfrom
the top surface of the throat plate.
Adjusttherearendheightofthefeeddogwithshafta,andfrontendheightwithshaftb.
Setscrew
Feed bar eccentric collar
Shaft a
Shaft b
Shaft a
Shaft b
1.0 ± 0.1 mm
1.0 ± 0.1 mm