– 99 –
Error
code
Description of error Cause Item to be checked
E081 Feed driving motor lock In the case the feed driving motor is
locked.
Check whether the feed driving motor
operates smoothly.
E204 USB insertion In the case the sewing machine is start-
ed up without removing the USB thumb
drive.
Remove the USB thumb drive.
E220 Warning against short-
age of grease
When the predetermined number of
stitches is reached.
Add grease to the specied points of
sewing machine and reset the error.
E221 Grease-shortage error In the case the sewing machine cannot
continue sewing since the predeter-
mined number of stitches is reached.
Add grease to the specied points of
sewing machine and reset the error.
E302 Head-tilt detection error
(When the safety switch
operates)
In the case the Tilt detection switch is
turned ON when the power to the sew-
ing machine remains ON.
Check whether the machine head is
tilted before turning OFF the power
switch (The sewing machine oper-
ation is prohibited for the sake of
safety.)
E303 Meniscus sensor error In the case the meniscus sensor signal
cannot be detected.
Check for a break in the motor encod-
er connector.
E402 Deletion disabled error In the case of attempting to delete the
pattern which is used in a cycle pattern.
In the case of attempting to delete the
custom pattern or condensation custom
which is used in a pattern.
E407 Wrong password In the case the password entered is
wrong.
E408 Shortage of number of
password characters
In the case the number of password
characters entered is not enough.
E411 Polygonal stitching pat-
tern registration disabled
error
In the case of attempting to create elev-
en or more polygonal stitching patterns.
E412 Custom pattern unregis-
tered error
In the case the custom pattern number
is faulty.
E413 Condensation custom
unregistered error
In the case the condensation custom
number is faulty.
E421
Continuous sewing pat-
tern registration rejection
error
In the case of attempting to create 11 or
more continuous sewing patterns.
E487
Condensation portion,
feed amount error
In the case the feed amount at the con-
densation portion exceeds the specied
feed range.
Reset the error. Then, re-input the
data.
Adjust the feed amount at the con-
densation portion of the pattern to a
value within the limit range.
E488
Normal stitch portion, re-
verse feed amount error
In the case the reverse feed amount at
the normal portion exceeds the specied
feed range.
Reset the error. Then, re-input the
data.
Adjust the reverse feed amount at
the normal portion of the pattern to a
value within the limit range.