– 98 –
5-7. List of errors
Error
code
Description of error Cause Item to be checked
E000 Execution of data initial-
ization (This is not an
error.)
• The existing control box has been re-
moved and a new one is mounted.
• In the case the initialization operation is
executed.
This is not a failure.
E007 Motor overload • In the case the machine head is locked.
• In the case of sewing extra-heavy weight
material that exceeds the guaranteed
material thickness.
• In the case the motor fails to rotate.
• In the case of the motor or driver failure.
• Check whether the pulley is entan-
gled with thread.
• Check whether the motor output con-
nector (4P) has loosened.
• Check whether the motor can be
turned smoothly by hand.
E009 Overtime of solenoid
energization
• In the case the length of solenoid ener-
gizing time has exceeded the assumed
one.
E011 Media is not inserted • In the case no media is inserted. • Turn the power OFF and check for a
media.
E012 Read error • In the case data stored on the media
cannot be read.
• Turn the power OFF and check for a
media.
E013 Write error • In the case data cannot be written on
the media.
• Turn the power OFF and check for a
media.
E014 Write protect • In the case the media is placed in the
write-prohibition state.
• Turn the power OFF and check for a
media.
E015 Format error • In the case formatting of the media can-
not be carried out.
• Turn the power OFF and check for a
media.
E016 External media over-ca-
pacity
• In the case the capacity of media is not
enough.
• Turn the power OFF and check for a
media.
E019 File size over • In the case of attempting to read the
custom pattern data or condensation
custom data which exceeds the max-
imum permissible data size into the
memory of sewing machine from the
USB thumb drive.
• Turn the power OFF and check the
USB thumb drive.
E022 File undetected • In the case of attempting to read a le
which is not stored in the USB thumb
drive into the operation panel.
E024 Pattern data size error • In the case the number of stitches con-
tained in data is too large when attempt-
ing to read the condensation custom
pattern data from the USB thumb drive.
E032 File compatibility error • In the case the le is not compatible. • Turn the power OFF and check for a
media.
E071 Motor output connector
slip-o
• In the case the motor connector has
slipped o.
• Check for looseness and slip-o of
the motor output connector.
E072 Motor overload when the
thread trimmer operates
• Same as E007. • Same as E007.
E079 Overload operation error • Load applied to the main shaft motor is
excessively large.