– 94 –
No. Item Setting range Unit
U038
Speed during one-shot stitching
The maximum number of revolutions during soft start diers with the machine
head.
100 to 5000 sti/min
U039
Start position of rotation
Set start position from neutral pedal potision. (Pedal Stroke)
10 to 1000
ー
U040
Start position of acceleration
Set accelerating position from neutral pedal position. (Pedal Stroke)
10 to 1000
ー
U041
Start position of lifting of presser foot
Set work clamp lift position from neutral pedal position. (Pedal Stroke)
-500 to -10
ー
U042
Start position of lowering of presser foot
Set work clamp fall position from neutral pedal position. (Pedal Stroke)
10 to 500
ー
U043
Start position of thread trimming
Set thread triming starting position from neutral pedal position. (Pedal Stroke)
-1000 to -100
ー
U044
Position that maximum sewing speed is reached
Set maximum speed reaching position from neutral pedal position. (Pedal Stroke)
10 to 15000
ー
U045
Pedal neutral-position correction value
Set neutral position of pedal sensor.
-150 to 150
ー
U047
Presser-foot lift nishing position
The position to which the presser foot goes up when the back part of the pedal is
depressed to its rst step. (1st-step spring position)
-1000 to -100
ー
U048
Function of lifting the presser foot by depressing the pedal
Whether or not the presser-foot lifting operation is carried out by depressing the
back part of pedal is set.
0: No operation / 1: Operation
0 to 1
ー
U049
Presser foot lowering time
The initial value diers depending on the machine head.
0 to 500 ms
U051
Correction of turning-ON of reverse feed stitching (at start)
-50 to 50 Degree
U052
Correction of turning-OFF of reverse feed stitching (at start)
-50 to 50 Degree
U053
Correction of turning-OFF of reverse feed stitching (at end)
-50 to 50 Degree
U054
Standby time until the presser foot starts going up
Time to be elapsed from the moment the pedal is depressed to the 1st step to the
moment the presser foot starts going up.
0 to 200 ms
U056
Reverse-rotation needle-up after thread trimming
The initial value diers with the machine head.
0: Reverse-rotation needle-up is not performed / 1: Reverse-rotation needle-up is
performed
0 to 1
ー
U057
Feed dog position at thread trimming
The feed dog height is xed to 0 (zero) at the time of thread trimming.
0: Not xed / 1: Fixed
0 to 1
ー
U059
Selection of revere feed stitching (at start) operation
0: By manually operating the pedal, etc. / 1: According to the preset reverse feed
sewing speed
0 to 1
ー
U060
Stop after reverse feed stitching (at start)
The stop function stops the sewing machine temporarily regardless of the operat-
ing status of the pedal.
0: OFF / 1: ON
0 to 1
ー
U064
Sewing-end reverse feed stitching, changeover speed
150 to 1000 sti/min