TP-6774 2/14a 25Section 4 Fuel System
4.3 Fuel Pump
The fuel pump transfers fuel from a source to the
injection pump.
Fuel Pump Test Procedure:
1. Remove the two leads at the bottom of the fuel
pump. The pump terminals are labeled (--) and (+).
SeeFigure4-5.
2. Connect the inlet side of the pump to a fuel source.
Disconnect the outlet hose from the fuel filter and
place the hose end in a container to catch the fuel.
3. Connect the positive (+) terminal of a 12-volt
battery to the positive terminal of the fuel pump.
Connect the negative terminal of the fuel pump to
the negative (--) terminal of the battery. You should
hear the pump operate and see fuel discharge from
the pump outlet. Replace the pump if it does not
operate.
4. Connect a pressure gauge to the outlet side of the
fuel pump. Repeat step 3
. SeeSection1forthe
specified fuel pump pressure ratings.
I-940
1
23
4
1. Fuel inlet
2. Negative (--) terminal
3. Positive (+) terminal
4. Fuel outlet
Figure 4-5 Fuel Pump
4.4 Governor
The centrifugal, mechanical governor keeps the engine
speed constant by automatically adjusting the amount
of fuel supplied to the engine according to changes in
the load. The governor requires no regular service. The
factory adjusts the governor during run-in, and further
adjustment should not be needed unless greatly varying
load conditions are encountered or if poor governor
control develops after extended usage.
60 Hz generator sets are designed to operate in the
range of 59-63 Hz (1800 rpm under full load and
1890 rpm under no load).
50 Hz generator sets are designed to operate in the
range of 49-53 Hz (1500 rpm under full load and 1590
rpm under no load).
To check the engine speed, use a frequency meter
connected to the load leads or use a hand tachometer. If
adjustment is needed, loosen the locking nut on the
speed adjusting screw. Turn the screw clockwise to
increase the speed (and frequency). To decrease the
speed, turn the screw counterclockwise. Tighten the
locking nut when the correct setting is reached. See
Figure 4-6.
1. Speed adjusting screw
2. Locking nut
3. Adjusting arm
3
2
1
Figure 4-6 Governor Adjustment
4.5 Fuel Solenoid
The generator set uses a 2-lead fuel solenoid. See
Section 1, Service Views for location. This solenoid has
lead 70A which energizes the coil during cranking,
opening fuel flow to the engine. Lead N is the common
ground.

Table of Contents

Other manuals for Kohler 6EKOD

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler 6EKOD and is the answer not in the manual?

Kohler 6EKOD Specifications

General IconGeneral
BrandKohler
Model6EKOD
CategoryMarine Equipment
LanguageEnglish

Related product manuals