(A) No bubbles in refrigerant flow: Suitable
(B) Some bubbles in refrigerant flow: Insufficient (bubbles pass
continuously)
(C) Colorless, transparent: No refrigerant
REMARK
When there are bubbles, the refrigerant (gas) level is low, so ask your Komatsu distributor to add refrigerant. If
the air conditioner continues to run with low refrigerant (gas) level, it will cause damage to the compressor.
METHOD FOR CLEANING AIR CONDITIONER AIR FILTERS
If the air filter at the suction port of the air conditioner unit or the air filter at the fresh air intake port become
clogged, the cooling or heating capacity will drop, so clean the filters.
1.
Open the cover (1) on the side of the cab.
2.
Pull out the air filter (fresh air filter).
3.
Clean the air filter (fresh air filter) with compressed air.
4.
Open the cover (2) at the rear left of the operator's seat.
5.
Pull out the air filter (recirculation air filter).
6.
Remove the dust sticking to the air filter (recirculation air
filter) with low compressed air or a soft brush.
METHOD FOR CHECKING DUMP BODY
Check that there are no cracks in the dump body.
1.
Clean the dump body so that you can check it easily.
2.
Check each portion of the dump body for damage.
If any cracks or abnormal wear are found, perform repairs.
Contact your Komatsu distributor for details of the repair procedure.
METHOD FOR CHECKING LENGTH OF SUSPENSION CYLINDER
If the machine reacts to the rough ground conditions when traveling, such as making high bounds or the cylinder
retracting and hitting the stopper, check the length of the suspension cylinder.
MAINTENANCE MAINTENANCE PROCEDURE
4-25