Rugby 620, Safety Directions
11
Labelling
1.7 Electromagnetic Compatibility EMC
Description The term Electromagnetic Compatibility is taken to mean the capability of the product
to function smoothly in an environment where electromagnetic radiation and electro-
static discharges are present, and without causing electromagnetic disturbances to
other equipment.
WARNING
Electromagnetic radiation can cause disturbances in other equipment.
Although the product meets the strict regulations and standards which are in force in
this respect, Leica Geosystems cannot completely exclude the possibility that other
equipment may be disturbed.
CAUTION
There is a risk that disturbances may be caused in other equipment if the product is
used with accessories from other manufacturers, for example field computers,
personal computers or other electronic equipment, non-standard cables or external
batteries.
Precautions:
Use only the equipment and accessories recommended by Leica Geosystems. When
combined with the product, they meet the strict requirements stipulated by the guide-
lines and standards. When using computers or other electronic equipment, pay atten-
tion to the information about electromagnetic compatibility provided by the manufac-
turer.
CAUTION
Disturbances caused by electromagnetic radiation can result in erroneous measure-
ments.
Although the product meets the strict regulations and standards which are in force in
this respect, Leica Geosystems cannot completely exclude the possibility that the
product may be disturbed by intense electromagnetic radiation, for example, near
radio transmitters, two-way radios or diesel generators.
Precautions:
Check the plausibility of results obtained under these conditions.
CAUTION
If the product is operated with connecting cables attached at only one of their two
ends, for example external supply cables, interface cables, the permitted level of elec-
tromagnetic radiation may be exceeded and the correct functioning of other products
may be impaired.
Precautions:
While the product is in use, connecting cables, for example product to external battery,
product to computer, must be connected at both ends.
Laser Radiation
Do not stare into the beam
Class 2 Laser Product
according to IEC 60825-1
(2007 - 03)
Po 2.70 mW
= 635 ± 10 nm
a) Laser beam
005758_001
a

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Leica Rugby 620 and is the answer not in the manual?

Leica Rugby 620 Specifications

General IconGeneral
Self-leveling range± 5°
IP ratingIP67
Working range with receiver800 m (2, 600 ft) diameter
Rotation speed600 rpm
Laser type635 nm
Power sourcealkaline batteries
Battery life60 hours
Operating temperature-20°C to +50°C
Self-leveling accuracy± 1.5 mm at 30 m (± 1/16 in at 100 ft)