Parameter data transfer
Consistent parameter data
8
l
111
EDSMF2133IB EN 5.0
Configuring consistent data
Consistency is achieved by an appropriate PROFIBUS master configuration. Please refer to
the corresponding documentation for your configuring software for this purpose.
I Tip!
Consistency configuration depends on the PROFIBUS master configuring
software. When using a Siemens−S5 PLC, please consider:
ƒ Consistency is switched on by any word in the consistent area
ƒ Consistency must be switched off by a specific switch−off word.
ƒ The type of CPU and consistency and the address area determine which
word switches off consistency.