Product description
Product features
3
l
14
EDSMF2133IB EN 5.0
3.3 Product features
ƒ Interface module for the PROFIBUS communication system with the
PROFIBUS−DP−V0 (DRIVECOM profile) and PROFIBUS−DP−V1 (PROFIdrive)
communication profiles
ƒ Drive profiles:
DRIVECOM profile "drive technology 20" (can be switched off)
PROFIdrive (can be switched off, state machine and PROFIdrive parameter data
channel)
ƒ Support of the I&M0 functionality for identifying the standard device
ƒ Automatic detection of the baud rate (9.6 kbps ... 12 Mbps)
ƒ Optionally up to 12 process data words (depending on the basic device)
ƒ Acyclic parameter access via DP−V1
ƒ Access to all Lenze parameters
ƒ External 24V supply for maintaining the PROFIBUS network if the standard device
fails
ƒ DIP switches for ...
Setting of the node address
Setting of the compatibility to the Lenze PROFIBUS communication module
EMF2131IB
ƒ LED status displays:
Voltage supply of the communication module
Connection from the communication module to the PROFIBUS network
Connection from the communication module to the standard device
Operating statuses of the standard device

Table of Contents

Other manuals for Lenze EMF2133IB

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze EMF2133IB and is the answer not in the manual?

Lenze EMF2133IB Specifications

General IconGeneral
BrandLenze
ModelEMF2133IB
CategoryControl Unit
LanguageEnglish

Related product manuals