Parameter data transfer
Lenze parameter sets
Parameter sets for Drive PLC and ECSxS / ECSxA axis modules
8
l
86
EDSMF2133IB EN 5.0
8.1.4 Parameter sets for Drive PLC and ECSxS / ECSxA axis modules
The Drive PLC and ECSxS / ECSxA axis modules each have a parameter set for storage in the
EEPROM. Another parameter set is stored in the main memory. This parameter set is called
"current" parameter set.
Addressing
l Only the current parameter set can be directly addressed via the bus.
l After switch−on, parameter set 1 is automatically loaded in the current parameter set.
) Note!
Changes within the current parameter set are lost after the controller is
switched off.
Code C0003 serves to save the current parameter set (see documentation of
the controller).