Installation Instructions Section 2
10
Part Number 000007345 2/14
Ice Machine Heat of Rejection
Ice machines, like other refrigeration equipment, reject
heat through the condenser. It is helpful to know the
amount of heat rejected by the ice machine when sizing
air conditioning equipment where self-contained air-
cooled ice machines are installed.
This information is also necessary when evaluating the
benefits of using water-cooled or remote condensers to
reduce air conditioning loads. The amount of heat added
to an air conditioned environment by an ice machine
using a water-cooled or remote condenser is negligible.
Knowing the amount of heat rejected is also important
when sizing a cooling tower for a water-cooled
condenser. Use the peak figure for sizing the cooling
tower.
Removing Drain Plug and Leveling the Ice
Storage Bin
1. Remove threaded plug from drain fitting.
2. Screw the leveling legs onto the bottom of the bin.
3. Screw the foot of each leg in as far as possible.
4. Move the bin into its final position.
5. Level the bin to assure that the bin door closes and
seals properly. Use a level on top of the bin. Turn the
base of each foot as necessary to level the bin.
6. Inspect bin gasket prior to ice machine installation.
(Manitowoc bins come with a closed cell foam
gasket installed along the top surface of the bin.)
7. Remove all panels from ice machine before lifting.
and installing on bin. Remove both front panels, top
cover, left and right side panels.
Air Baffle
Self-Contained Air-cooled Only
The air-cooled baffle prevents condenser air from
recirculating. To install:
1. Loosen the back panel screws next to the
condenser.
2. Align the keyhole slots in the air baffle with the screw
holes and slide the baffle down to lock in place.
Series
Ice Machine
Heat of Rejection
B.T.U./Hour
Air Conditioning
Because the heat of rejection varies during the ice making cycle,
the figure shown is an average.
* Indicates Preliminary Data
Peak
I0300 4600 5450
I0320 3300 4500
I0450 5400 6300
I0500 6100 6900
I0520 5400 6300
I0600 9000 13900
I0850 13000 16000
I0906 13000 16000
I1000 16250 18600
I1100 16250 18600
I1200 20700 24500
I1400 23500 27000
I1800 30000 35000
To avoid instability the bin/dispenser must be
installed in an area capable of supporting the weight
of the bin/dispenser, ice machine and a full bin of ice
(48" models 1000 lbs - 454 kg, 30" models 750 lbs
340 kgs). The bin/dispenser must be level side to
side and front to back before installing the ice
machine.
The legs must be screwed in tightly to prevent them