EasyManuals Logo
Home>Manitowoc>Ice Maker>Indigo Series

Manitowoc Indigo Series Installation, Use & Care Manual

Manitowoc Indigo Series
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #44 background imageLoading...
Page #44 background image
Customer Support Section 5
44
Part Number 000007345 2/14
Safety Limit Feature
In addition to the standard safety controls, such as the
high pressure cutout, your Manitowoc ice machine
features built-in safety limits which will stop the ice
machine if conditions arise which could cause a major
component failure.
Before calling for service, re-start the ice machine using
the following procedure:
1. Press the power button, the display reads “Off”.
Press the power button again and the display reads
“Making Ice”.
A. If the safety limit feature has stopped the ice
machine, it will restart after a short delay.
Proceed to step 2.
B. If the ice machine does not restart, see “Ice
machine does not operate” on the previous
page.
2. Allow the ice machine to run to determine if the
condition repeats.
A. If the ice machine stops again, the condition has
repeated. Call for service.
B. If the ice machine continues to run, the condition
has corrected itself. Allow the ice machine to
continue running.
Problem Possible Cause To Correct
Ice machine produces shallow or
incomplete cubes, or the ice fill pattern on
the evaporator is incomplete.
Ice thickness probe is out of adjustment. Adjust the ice thickness probe.
(See Section 4)
Water trough level is too low. Check the water level probe for damage.
(See Section 3)
Water inlet valve filter screen is dirty. Remove the water inlet valve and clean
the filter screen. (See Section 4)
Water filtration is poor. Replace the filter.
Hot incoming water. Connect the ice machine to a cold water
supply. (See Section 2)
Water inlet valve is not working. Replace the water inlet valve.
Incorrect incoming water pressure. Water pressure must be 20-80 psi
(140 kPa - 550 kPa).
Ice machine is not level. Level the ice machine. (See Section 2)
Low ice capacity. Water inlet valve filter screen is dirty. Remove the water inlet valve and clean
the filter screen.
Incoming water supply is shut off. Open the water service valve.
Water inlet valve stuck open or leaking. Press the power button and turn off the
ice machine, if water continues to enter
water trough replace the water inlet
valve.
The condenser is dirty. Clean the condenser. (See Section 4)
High air temperature entering condenser. Air temperature must not exceed 120°F
(39°C).
The harvest assist air compressor is not
functioning.
Call for service.

Table of Contents

Other manuals for Manitowoc Indigo Series