eikon e2s Service and Repair Manual UL 109
Move the survey meter probe across all casework joins and vent
areas including those marked in yellow, shown opposite.
6.
When the magnetron circuit stops after 30 seconds, change the
water and re-select the test to continue.
7.
Select the red ‘X’ on the display to stop the test at any time.
Readings must be below 5 mW/cm².
CAUTION:
If a level greater than 5 mW/cm² is observed, report this to the
Merrychef Service Department immediately. Don't use the
appliance hereafter.
9.
Note any leakage that is observed in terms of the level and
position on the appliance. Keep this information with the service
documentation.