eikon e2s Service and Repair Manual UL 110
Temperature Control test: measuring the cavity temperature
NOTE:
Re-calibrating the temperature sensor / thermocouple with the SRB is normally only required when the
thermocouple has been replaced or the appliance is under or over cooking.
1.
Place the probe of a temperature reader onto a heat sink or a
metal plate in the centre of the oven cavity and close the door.
2.
Select ‘Temperature Control Test’ from the service mode tests.
The cavity heats up and cycles at the maximum set point tem-
perature over 30 minutes.
3.
Once the appliance is up to maximum temperature check for a
stable temperature reading.
4.
Select the red 'X' to finish the test, if necessary.