Vision System Manual
143
Matrix
Programming the System
What’s this?
Vision is a flexible system and can be programmed to suit your needs. Programming can be done at three
levels:
• System Engineer level
At this level, System Engineer does the programming. This is called System Engineer mode.
• System Administrator level
At this level, System Administrator does the programming. This is called System Administrator mode.
• User level
At this level, User does the programming for himself for features like Alarms, Personal memory. For more
details, please refer respective sections.
Vision has fixed number of station ports and trunk ports each port has a hardware port, a software port and a
flexible number associated to it. Following table clarifies this in more details.
Flexible Number
(default)
Hardware Port
Number
Software Port
Number
21 01
00
22 02 01
23 03 02
24 04 03
25 05 04
26 06 05
27 07 06
28 08 07
29 09 08
• All the programming either from SE/SA mode is based on software port. Whereas the user programming like
Personal Memory, Dynamic Lock, etc. is based on flexible number.
• Hardware port number is not used anywhere.
• A software port number can be assigned any flexible number.
• The relation between hardware and software port is fixed and not programmable.