Important: To avoid the danger of
toxic fumes, please observe the
Warning and Safety instructions.
This is especially crucial when using
the cooker hood at the same time as
another heating appliance which
relies on air from the same room.
The cooker hood should be installed
according to local and national
building regulations. Seek approval
from the building inspector where
necessary.
Only use smooth pipes or flexible
hoses made from non-flammable
materials for the extraction ducting.
To achieve the greatest possible air
extraction with the lowest noise level,
please note the following:
To ensure efficient air extraction, the
diameter of the exhaust ducting
should not be less than 150 mm.
If flat ducting is being used, the
cross-sectional area must not be
smaller than the cross-sectional area
of the exhaust connection.
All ducting, pipework and fittings
must be of non-flammable materials.
The exhaust ducting should be as
short and straight as possible.
Only use wide radius bends.
The exhaust ducting should not be
kinked or compressed.
Ensure that all connections are
strong and airtight.
Where ducting is horizontal, it must
be laid to slope away at at least 1 cm
per metre. This is to ensure that
condensate cannot drain back into
the cooker hood.
If the exhaust air is to be ducted into
the open air, the installation of a
telescopic wall vent or roof vent
(available as an optional accessory)
is recommended.
If the exhaust air is to be ducted into
a vent flue, the ducting must be
directed in the flow direction of the
flue.
Important:
If the exhaust ducting is to run through
rooms, ceiling space etc. where there
may be great variations in temperature
between the different areas, the
problem of condensation will need to
be addressed. The exhaust ducting will
need to be suitably insulated.
Connection for air extraction
30

Other manuals for Miele DA 3360

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Miele DA 3360 and is the answer not in the manual?

Miele DA 3360 Specifications

General IconGeneral
TypeBuilt-in
Cord length1.5 m
Product colorStainless steel
Built-in display-
Exhaust connection diameter150 mm
Built-in capabilityYes
Installation compartment dimensions (WxDxH)595 x 275 x 414 mm
Intensive speedNo
Number of speeds3
Type of extractionDucted/Recirculating
Maximum extraction power320 m³/h
Maximum recirculating power200 m³/h
Minimum distance from gas hob650 mm
Noise level (recirculation mode)67 dB
Minimum distance from electric hob450 mm
Current10 A
AC input voltage230 V
Power consumption (typical)210 W
Number of filters1 pc(s)
Bulb typeHalogen
Bulb power50 W
Number of bulbs2 bulb(s)
Weight and Dimensions IconWeight and Dimensions
Depth275 mm
Width595 mm
Height414 mm
Weight12000 g