Parameter write prohibit selection[ll]
Prevents
parameters
from
being
written
via the key pad.
Setting value Write prohibition function
0
Parameter
writing permitted (during operation and
stop)
1
Parameter
write prohibited
(Note)
[F actory setting] ..•". 0
(Note)
Parameter No. Ill] can be written in.
Er1
will display when writing of other parameters
is attempted. (Release the error display with the MODE kev.)
Reverse rotation preventionselection
IIID
This
is set to prevent reverse
rotation
fault
resulting
from
the
mis-input
of the
start
signal
Setting value Rotation direction
0 Both forward/reverse
rotation
1 Reverse
rotation
prohibited
2
Forward
rotation
prohibited
(Note)
(Note)
The inverter will drive the motor in
reverse with the RUN key when set to
M2
M•
[Factory
setting)
......
0
This
function is
valid
for both
the
key pad
operation
and
external
operation.
-34-

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi FREQROL-U100 and is the answer not in the manual?

Mitsubishi FREQROL-U100 Specifications

General IconGeneral
BrandMitsubishi
ModelFREQROL-U100
CategoryInverter
LanguageEnglish

Related product manuals