Power supply module
AI S61 P
A1 S62P
:WIRING
Transformer capacity
1
IO
VA
x
n
110VAxn
I
I
Chapter
5:
Wiring
I
This chapter explains the wiring instructions for the AIS PLC system.
IWiring instructions
for
the
power supply module
I
Below are the wiring instructions for the power supply modules of the AIS PLC.
1. If the fluctuations of the power supply modules incoming voltage are larger
than permitted by the specification of the module, a constant voltage
transformer should be used as shown below.
Constant
Voltage
Transformer
2. If the incoming power supply to the module generates noise outside the
specifications of the power supply module, then an insulating transformer
should be used as shown below.
Insulating transformer Insulating transformer
3. When a power transformer
or
insulating transformer
is
used to reduce the
voltage from 200 VAC to 100 VAC, use one which has a capacity greater
than shown in the table below.
n
=
the number of power supply modules
52

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi MELSEC A1S62P and is the answer not in the manual?

Mitsubishi MELSEC A1S62P Specifications

General IconGeneral
BrandMitsubishi
ModelMELSEC A1S62P
CategoryController
LanguageEnglish

Related product manuals