Output instructions
Bit
device, timer, counter output
(OUT)
Device number
(a) OUT
(v,
M,
L,
S,
B,
F)
This OUT instruction outputs the operation result for the instructions preceding the OUT
instruction.
pg
(TI
Set value
(1
to
32767)
K50
Device number
(TO
to
255)
value (Contents of data register)
D1O
Device number
(TO
to
255)
~~
(b) OUT
cr)
This OUT instruction uses the operation result for the instructions preceding the OUT
instruction. If the operation result is
ON,
then
the
coil of the timer is turned
ON
and the
timer counts up
to
its set value. When the operation result
of
the instructions preceding
the OUT instruction changes from
ON
to
OFF,
the following occurs
106