Part Number: WBL-95-156 REV002 11
Section 1 General Information
SYSTEM PRESSURES
Water Supply to the Unit
n
Warning
Do not supply more than 80 psi (0.551 MPa , 551 kPa,
5.51 bar) Plain or Carbonated Water to the unit, excessive
pressure to product pumps may cause failure.
This table shows the Minimum / Maximum supply of Water
required at the rear of the machine at no flow conditions.
MINIMUM MAXIMUM
Plain Water
Supply
40 psi
(0.276 MPa , 276 kPa, 2.76 bar)
80 psi
(0.552 MPa, 552 kPa, 5.52 bar)
Important
Minimum water pressure supplied to the machine needs
to be greater than the 35 psi (0.241 MPa , 241 kPa, 2.41
bar) required during flowing conditions for pressure to
be regulated properly.
REGULATOR SETTINGS & LOCATION
Models FB081TF
NOTE: The regulator is located behind the left side panel.
Plain Water
Regulator
35 psi
(0.241 MPa , 241
kPa, 2.41 bar)
Flowing
Regulator Settings
Important
Water requires the pressure measurement to be taken
only when rinse water is spraying or dispensing (flowing
conditions).
Important
Water pressure affects the blender area cleaning, a
water booster may be required if pressure is too low.
REGULATOR SETTINGS (During Flowing Conditions)
Plain Water
35 psi
(0.241 MPa , 241 kPa, 2.41 bar)

Table of Contents

Other manuals for Multiplex FreshBlender

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Multiplex FreshBlender and is the answer not in the manual?

Multiplex FreshBlender Specifications

General IconGeneral
BrandMultiplex
ModelFreshBlender
CategoryDispenser
LanguageEnglish

Related product manuals