ENGLISH – 15
EN
6.2 LEVEL 1 PROGRAMMING (ON-OFF)
All the Level 1 functions are factory-set to “OFF” and can be modied at any time. To check the various functions, refer to “Table 5”.
6.2.1 Level 1 programming procedure
m
The user has maximum 10 seconds to press the buttons consecutively during the programming procedure,
after which time the procedure terminates automatically and memorises the changes made up to then.
To perform Level 1 programming:
1. press and hold the
g
button until LED “L1” starts ashing
2. release the
g
button when LED “L1” starts ashing
3. press the
f
or
h
button to move the ashing LED to the LED associated with the function to be modied
4. press the
g
button to change the status of the function:
– short ash = OFF
– long ash = ON
5. wait 10 seconds (maximum time) to exit the programming mode.
l
To set other functions to “ON” or “OFF”, while the procedure is running, repeat points 2 and 3 during the phase
itself.
Table 5
LEVEL 1 FUNCTIONS (ON-OFF)
LED Function Description
L1 Automatic closing
Function ENABLED: after an opening manoeuvre there is a pause (equal to the set pause time), after
which the control unit automatically starts a closing manoeuvre. The pause time is set by default to 30
seconds.
Function NOT ENABLED: the system works in “semi-automatic” mode.
L2 Close after photo
Function ENABLED: if the photocells intervene during the opening or closing manoeuvre, the pause time
drops to 5 seconds regardless of the set “pause time”. With “automatic closing” disabled, if the photocells
intervene during the opening or closing manoeuvre, the “automatic closing” activates with the set “pause
time”.
L3 Always Close
Function ENABLED: in the event of a blackout, even of short duration, 10 seconds after the electricity
is restored the control unit detects that the gate is open and automatically starts a closing manoeuvre,
preceded by 5 seconds of pre-ashing.
Function DISABLED: when the electricity is restored, the gate remains in the same position.
L4 Ramming function
Function ENABLED: before the opening manoeuvre starts (starting from the closed gate position), a brief
closing manoeuvre is triggered to facilitate unlocking of the electric lock.
L5
Warning /
Courtesy light
Function ENABLED: the “warning light” output (FLASH - 120/230 Va 50/60 Hz) switches its operation to
“courtesy light”.
Function NOT ENABLED:: the output functions as a warning light.
L6 Pre-ashing
Function ENABLED: the warning light starts ashing 3 seconds before the start of the manoeuvre to
signal in advance a dangerous situation.
Function NOT ENABLED: the warning light starts ashing when the manoeuvre starts.
L7
“Close” becomes
“Partial Open 1”
Function ENABLED: the “Close” input of the control unit switches its operation to “Partial Open 1”.
L8
Pressure
maintenance
Function ENABLED: after 4 hours during which the gate has been permanently closed, a brief closing
manoeuvre is triggered to reload the hydraulic circuit pressure.
6.3 LEVEL 2 PROGRAMMING (ADJUSTABLE PARAMETERS)
All the Level 2 parameters are factory-set as shown in the “GREY” sections in “Table 6” and can be modied at any time. The pa-
rameters can be set to a scale of 1 to 8. To check the value corresponding to each LED, refer to “Table 6”.
6.3.1 Level 2 programming procedure
m
The user has maximum 10 seconds to press the buttons consecutively during the programming procedure,
after which time the procedure terminates automatically and memorises the changes made up to then.
To perform Level 2 programming:
1. press and hold the
g
button until LED “L1” starts ashing
2. release the
g
button when LED “L1” starts ashing
3. press the
f
or
h
button to move the ashing LED to the “entry LED” associated with the parameter to be
modied
4. press and hold the
g
button. With the
g
button pressed:
– wait roughly 3 seconds, until the LED representing the current level of the parameter to be modied lights up
– press the
f
or
h
button to shift the LED associated with the parameter’s value
5. release the
g
button
6. wait 10 seconds (maximum time) to exit the programming mode.