EasyManuals Logo
Home>Nice>Garage Door Opener>ROBUS RB250HS

Nice ROBUS RB250HS Instructions And Warnings For Installation And Use

Default Icon
212 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
EN
English – 5
2.2) Typical system
Figure 2 shows a typical system for automating a sliding gate using ROBUS
2
1 Key-operated selector switch
2 Photocells on post
3 Photocells
4 Main fixed edge (optional)
5 Main movable edge
6 “Open” stop bracket
7 Rack
8 Secondary fixed edge (optional)
9 Flashing light with incorporated aerial
10 ROBUS
11 “Closed” stop bracket
12 Secondary movable edge (optional)
13 Radio-transmitter
2.3) List of cables
Figure 2 shows the cables needed for the connection of the devices in a typical installation; table 3 shows the cable characteristics.
!
The cables used must be suitable for the type of installation; for example, an H03VV-F type cable is recommended for indo-
or applications, while H07RN-F is suitable for outdoor applications.
Note 1: power supply cable longer than 30 m may be used provided it has a larger gauge, e.g. 3x2,5mm
2
, and that a safety grounding
system is provided near the automation unit.
Note 2: If the “BLUEBUS” cable is longer than 30 m, up to 50 m, a 2x1mm
2
cable is needed.
Note 3: A single 2x0,5mm
2
cable can be used instead of two 4x0,5mm
2
cables.
Note 4: Please refer to Chapter “7.3.2 STOP Input” in situations where there is more than one edge, for information about the type of con-
nection recommended by the manufacturer.
Note 5: special devices which enable connection even when the leaf is moving must be used to connect movable edges to sliding leaves.
Connection Cable type Maximum length allowed
A: Power line 1 3x1,5mm
2
cable
30m (note 1)
B: Flashing light with aerial 1 2x0,5mm
2
cable 20m
1 RG58 type shielded cable 20m (recommended less than 5 m)
C: Photocells 1 2x0,5mm
2
cable 30m (note 2)
D: Key-operated selector switch 2 2x0,5mm
2
cable (note 3) 50m
E: Fixed edges 1 2x0,5mm
2
cable (note 4) 30m
F: Movable edges 1 2x0,5mm
2
cable (note 4) 30m (note 5)
Table 3: List of cables
2
4 3 3 8
10
2
6
11
7
9
13
1251
E C F
D
C
F
A
B

Table of Contents

Other manuals for Nice ROBUS RB250HS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nice ROBUS RB250HS and is the answer not in the manual?

Nice ROBUS RB250HS Specifications

General IconGeneral
BrandNice
ModelROBUS RB250HS
CategoryGarage Door Opener