15
EN
TECHNICAL SPECIFICATIONS OF PRODUCT
WARNINGS: •Alltechnicalspecicationsstatedinthissectionrefertoanambienttemperatureof20°C(±5°C).•NiceS.p.a.reservestherighttoapply
modicationstoproductsatanytimewhendeemednecessary,maintainingthesameintendeduseandfunctionality.
Model:
RUN1500
RUN1200HS
Type Electromechanical gearmotor for automatic movement of sliding gates for industrial use complete with elec-
tronic control unit.
Pinion
Maximumtorqueonstart-up[cor-
respondstoabilityofgeneratingthe
forcerequiredtomovetheleaf]
35Nm
(1000N)
27.4Nm
(790N)
Nominaltorque[correspondstothe
ability of generating the force to main-
tain the leaf in movement]
20Nm
(560N)
10.3Nm
(286N)
Speed(noload)
15 m/min
22 m/min
Speed(atnominaltorque)
10.8 m/min
19 m/min
Maximumfrequencyofoperating
cycles(atnominaltorque)
15 cycles/hour (365 cycles/day), for a gate of 15m
(equal to a cycle of 63%), (
15 cycles/hour (365 cycles/day), for a gate of 15m
(equal to a cycle of 63%), (the control unit limits cycles
tothemaximumnumberspeciedintables2and3)**
Maximum time of continuous
operation(atnominaltorque)
60 minutes (the control unit limits continuous
operation tothemaximumlimitsasspecifiedintables
2and3)***
60 minutes (the control unit limits continuous operation
tothemaximumlimitsasspeciedintables2and3)***
Operating limits IngeneralRUNisdesignedfortheautomationofgateswiththeweightsandlengthsasspecied
Durability Estimatedbetween150.000cyclesand450.000cyclesaccordingtoconditionsspeciedinTable4
Power:RUN400HS-1200HS 230VAC(+10%-15%)50Hz.
Maximum power absorption on
start-up[correspondingtoAmps]
700W
(3,5A)
700W
(3,5A)
Maximum power absorption on start-
up[correspondingtoAmps]
400W
(1,8A)
400W
(1,8A)
Insulation class 1 (safety earthing required)
Flashing light output For 2 Flashing lights LUCYB (lamp 12V, 21W)
Gateopenindicatoroutput For 1 24V lamo of maximum 4W (output voltage may vary between -30 and +50% and can also control small
relays)
BLUEBUS output One output with a maximum load of 15 BlueBus units
STOP input Fornormallyclosedornormallyopencontacts,for8.2kΩconstantresistance;withself-recognition(anyvaria-
tionfromthememorizedstatuscausesthe“STOP”command)
Step-by-step input For normally open contacts (contact closure generates S.S. command)
OPEN input For normally open contacts (contact closure generates OPEN command)
CLOSE input For normally open contacts (contact closure generates the CLOSE command)
Radioconnector SM connector for receivers SMXI; SMXIS or ONEXI
RadioANTENNAinput InputANTENNARadio52ΩforcabletypeRG58orsimilar
Programmable functions 8 ON-OFF type functions and 8 settable function (see tables 7 and 9)
Functionsinself-learningmode Self-learning of devices connected to BlueBus output
Self-learningof“STOP”devicetype(contactNO,NCor8,2KΩresistance)
Self-learning of gate length and calculation of deceleration and partial opening points
Operating temperature -20°C ÷ 50°C
Useinacid,salineorpotentiallyexplo-
sive atmosphere
No
Protection rating IP 44
Dimensionsandweight 400 x 255 h 390; 24.5kg