18 – English
6
PROGRAMMING
6.1 - Programming keys
A number of programmable functions are available on the SPIN control unit; they can be adjusted using 4 buttons on the control unit and are
displayed with 8 LEDs: L1….L4 .
2/(-RCDE@TKSRDSSHMFRRGNTKCR@SHREXLNRSQDPTHQDLDMSRATSB@MADLNCHjDC@S@MXSHLDTRHMFSGD@OOQNOQH@SDOQNFQ@LLHMFOQNBDCTQDRDD
par. 6.6.2
Tasti Funzione
Close
Stop/Set
L1
L2
L3
Open
Open S
The “OPEN” key enables the user to control the opening of the door or move the program-
ming point upwards.
Stop /
Set
The “STOP” key enables the user to stop the manoeuvre.
If pressed down for more than 5 seconds it enables the user to enter pro gramming.
Close T
The “CLOSE” key enables the user to control the closing of the door or move the program-
ming point downwards
6.2 - Recognition of the devices
ESDQXNTG@UDGNNJDCTODKDBSQHB@KONVDQXNTLTRS@BPTHQDSGDCDUHBDRBNMMDBSDCSNSGD!KTD!42@MC23./HMOTSRHMCHB@SDCAXSGDk@RGHMF
of LEDs L1 and L2).
WARNING! - The device acquisition phase must be performed even if there is no device connected.
01.
Hold down the S and Set keys together.
Close
Open
Stop/Set
L1
L2
L3
02. 1DKD@RDSGDJDXRSGDM+$#R+@MC+RS@QSk@RGHMFQ@OHCKX@ESDQ@OOQNWRDB
03. 6@HSENQ@EDVRDBNMCRENQSGDBNMSQNKTMHSSNjMHRGQDBNFMHRHMFSGDCDUHBDR
04. The STOP LED must remain on when the recognitions stage has been completed, while LEDs L1 and L2 will switch off (LEDs L3 and
+VHKKDUDMST@KKXRS@QSk@RGHMF
The connected devices recognition stage can be repeated at any time, even after installation, e.g. if another device is added. Please refer to
Paragraph 8.1 for information about how to carry out another recognition process.
6.3 - Acquisition of the door opening and closing positions
After recognizing the devices the control unit must be made to recognize the opening and closing positions of the door. In this phase, the door
stroke from the mechanical closing stop to the mechanical opening stop is detected.
Ensure that the drive belt is correctly tensioned and that the two mechanical stops are fully secured.
01. Engage the carriage.
02.
Hold down the Close T and Set keys together.
Close
Stop/Set
L1
L2
L3
Open
03. Release the keys when the manoeuvre (after approx. 3s)
04. Wait for the control unit to complete the recognition phase: closing, opening and closing again of the door. The courtesy light will now
RS@QSk@RGHMFVGHKDV@HSHMFENQSGDENQBDRDDJOQNBDCTQDSNRS@QS