8 – English
EN
PARAMETER SETTINGS ON THE INVERTER
It is possible to set a number of parameters on the inverter
Error/
status
50_0
Currentoutputfrequency
Regularoperation
Stop(outputsU,V,Wblocked)
LOWsignalonterminal28
Setterminal28onHIGH
Outputfrequency=0Hz
OutputsU,V,Wblocked
Quickstopviadigitalinput
DisableQuickstop
Thecurrentlimitwasreached
Undervoltageintheintermediatecircuit
Overvoltageintheintermediatecircuit
duringtheprocess(warning)
Automaticifovervoltageduration<1s,
otherwiseerrorDU
Modifiableonlyiftheregulatorisseton
OFF
orinh
rC
Theremotecontrolisenabled
Anattempttousebuttonsonthefrontof
theregulatorwasdetected
Thebuttonsonthefront
aredisabledif
theremotecontrolisenabled
Ad
ErrorA/Dinverter
Assistanceservice
cF
ThedatainEPMareinvalid
Thedataarenotvalidfortheregulator
UseEPMwithvaliddata,uploadthe
factorysettings
CF
Dataerror
9F
TheOEMdataareinvalid
F1
EPMerror
EPMismissingorisdamaged
DisableandreplacetheEPM
CF9
Digitalinputnotuniquely
assigned
E1...E3havebeenassignedthesamedigital
signals
Everydigitalsignalcanbeusedonlyone
time
Only"UP"oronly"DOWN"used
Assignthemissingdigitalsignaltoa
secondterminal
Thebrakingresistorsareoverheated
Increasetheprocesstime
Adigitalinputconfiguredwith"TRIPSet"is
enabled
Eliminatetheexternalfault
FC5
Internalfault
ContactourAssistanceService
Code
Name
Adjustmentrange
Preset
C10
Minimumoutputfrequency
1520Hz
15Hz
C11
Maximumoutputfrequency
50150Hz
with0.75kW10Hz
from1.5kWto5.5kw80Hz
C12
Speedincreasetime
1.01.8s
1.0s
C13 Performancetime 0.71.2s
C16
Booster
adjustinsmallstepsmax.2%inonesteponly
Asettingtoohighortoolowjeopardisesdooroperation
040%
10%
C17
Frequencythreshold(Qmin) 13.518.5Hz
13.5Hz
C01
Speedincreasetime(2) 0.40.8s
0.4s
C02
Performancetime(2) 0.20.5s
0.2s
C08
Relayoutputconfiguration 08
0withoperatingcurrentbrake
2withspringforcebrake
7inverterbrakerelaynotused