8 – English
EN
PARAMETER SETTINGS ON THE INVERTER
It is possible to set a number of parameters on the inverter
Error/
status
Description
Cause
Remedy
50_0
Currentoutputfrequency
Regularoperation
OFF
Stop(outputsU,V,Wblocked)
LOWsignalonterminal28
Setterminal28onHIGH
STP
Outputfrequency=0Hz
OutputsU,V,Wblocked
Quickstopviadigitalinput
DisableQuickstop
CL
Thecurrentlimitwasreached
Adjustableoverload
Automatic
LU
Undervoltageintheintermediatecircuit
Mainsvoltagetoolow
Checkthemainsvoltage
dEC
Overvoltageintheintermediatecircuit
duringtheprocess(warning)
Processtimeveryshort
Automaticifovervoltageduration<1s,
otherwiseerrorDU
nED
Noaccesstothecode
Modifiableonlyiftheregulatorisseton
OFF
orinh
Setterminal28onLOW
rC
Theremotecontrolisenabled
Anattempttousebuttonsonthefrontof
theregulatorwasdetected
Thebuttonsonthefront
aredisabledif
theremotecontrolisenabled
Contactour
Ad
ErrorA/Dinverter
Assistanceservice
cF
ThedatainEPMareinvalid
Thedataarenotvalidfortheregulator
UseEPMwithvaliddata,uploadthe
factorysettings
CF
Dataerror
9F
TheOEMdataareinvalid
F1
EPMerror
EPMismissingorisdamaged
DisableandreplacetheEPM
CF9
Digitalinputnotuniquely
assigned
E1...E3havebeenassignedthesamedigital
signals
Everydigitalsignalcanbeusedonlyone
time
Only"UP"oronly"DOWN"used
Assignthemissingdigitalsignaltoa
secondterminal
dF
Errorbrakingchopper
Thebrakingresistorsareoverheated
Increasetheprocesstime
EEr
Externalfault
Adigitalinputconfiguredwith"TRIPSet"is
enabled
Eliminatetheexternalfault
FC5
F2....F0
Internalfault
ContactourAssistanceService
Code
Name
Adjustmentrange
Preset
C10
Minimumoutputfrequency
1520Hz
15Hz
C11
Maximumoutputfrequency
50150Hz
with0.75kW10Hz
from1.5kWto5.5kw80Hz
C12
Speedincreasetime
1.01.8s
1.0s
C13 Performancetime 0.71.2s
0.7s
C16
Booster
adjustinsmallstepsmax.2%inonesteponly
Asettingtoohighortoolowjeopardisesdooroperation
040%
10%
C17
Frequencythreshold(Qmin) 13.518.5Hz
13.5Hz
C01
Speedincreasetime(2) 0.40.8s
0.4s
C02
Performancetime(2) 0.20.5s
0.2s
C08
Relayoutputconfiguration 08
0withoperatingcurrentbrake
2withspringforcebrake
7inverterbrakerelaynotused