EN
English – 9
OPERATION CURVES
(FU)
C12
(FU)
C12
(FU)
C13
(FU)
C13
(UST1FU)
Poti2
(UST1FU)
Poti3
(UST1FU)
Poti1
(UST1FU)
Poti1
(X5)
P8
(X5)
P9
Operation curves with parameter setting assigned
Shortcircuitoroverload
Lookforthecauseoftheshortcircuit,
checktheline
Capacitivechargingcurrentof
themotorlinetoohigh
Useashortermotorlinewithlower
chargingcurrent
Timeforgoingintofullspeed(C12,c01)too
short
Increasethetimeforgoingintofull
speed
Checkthesizingoftheregulator
Overloadfrequentandlengthy
Checkthesizingoftheregulator
Motorphasewithearthcontact
Checkthemotor/motorline
Capacitivechargingcurrentof
themotorlinetoohigh
Useashortermotorlinewithlower
chargingcurrent
Thermalmotoroverloaddueto:unreliable
continuouscurrent,frequentortoolengthy
accelerationprocesses
Checkthesizeoftheregulator
Checkthesettingofc20
Regulatorovertemperature
Spaceinsidetheregulatortoohot
Reducetheloadoftheregulator
Improvecooling
Overvoltageintheintermediate
circuitduringtheprocess
(warning)
Processtimeveryshortormotorin
generatormode
Increasetheprocesstimeorusethe
optionfordynamicbraking
Earthcontactmotorside
Checkthemotor/motorline(Separate
themotorfromtheregulator)