30
GEO module
Settings for the geothermal heat pump.
> GEO module
Heating curve
Language
The ventilation unit is factory set to Danish language. You can change the texts to other languages.
>Language (DK - Sprog)
> Heating - cooling simultane-
ously
Settings:
Standard setting:
Description:
No / Yes
No
If you press “yes” here, the central heating will be on while coo-
ling is provided by the ventilation at the same time.
> Room/outdoor temp. compen-
sation
> Temperature control Settings:
Standard setting:
Description:
Compressor min. / Outdoor temperature / Room / Outdoor +
Room
Compressor min.
You can select from min. compressor temperature, outdoor
temperature, room temperature or outdoor and room tempe-
rature.
> Outdoor temp. curve Settings:
Standard setting:
Description:
Manual / Curve 1 10
Manual
Manual: Here you can set curve control manually.
Curve 1 10: Here you select which curve the control system is
to regulate in accordance with.
> Max. room compensation Settings:
Standard setting:
Description:
-45 100 °C
5 °C
Offset in relation to the selected curve.
Max. temperature
Min. temperature
Supply air temperature
Outdoor temperature
> Danish Description: Select the desired language in the user panel.
20
-20-15-10-505101520
30
40
50
60
70
80
90