Domestic hot water
Fejl og løsninger varmt brugsvand
Central heating
Errors and solutions central heating
Problem Mulig årsag Løsning
Aggregatet producerer ikke nok varmt
brugsvand
Filtrene kan være tilstoppet, så der ikke
kommer luft nok igennem til aggregatet.
Det kan ske, hvis filtrene ikke skiftes
hyppigt nok.
Det kan ske, hvis aggregatet har stået og
kørt under byggeriet, og filtrene derfor
er fyldt med støv og skidt.
Skift filtrene og indstil evt. filterskift til
kortere interval.
Problem Possible cause Solution
The telestates call for heat, but the heat
pump does not start
During the spring and autumn transition
periods, some space telestates may call
for heat, but the heat pump does not
start.
This may be because the temperature in
the extract air is warm enough compared
to the temperature set in the control
panel. That is, the exhaust air is an
average of the room's room temperatu-
res, as some rooms are hot and others
are cold.
Since the ventilation section considers
the average temperature of the house to
be high enough, it blocks the heat pump
from running. This does it to save energy
and to prevent the ventilation part and
the heat pump part from counteracting
each other.
If you still want to heat in some rooms,
despite the average temperature of the
house being warm enough, you can acti-
vate this function below: Settings / Cen-
tral heating in the Menu item: Cooling and
heating at the same time.
This means that the cooperation bet-
ween the ventilation part and the heat
pump part ends, and if there is a need for
heat in some rooms, the heat pump will
start even if the ventilation part detects
that the house is warm enough.

Table of Contents

Other manuals for nilan Compact P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the nilan Compact P and is the answer not in the manual?

nilan Compact P Specifications

General IconGeneral
Brandnilan
ModelCompact P
CategoryHeat Pump
LanguageEnglish

Related product manuals