38 NFS-320/E/C, NFS-320SYS/E Operations Manual — P/N 52747:E1 06/16/2011
Read Status Operation Viewing and Printing a Read Status
Device Status The status of the module: control/relay module [On (device active) OFF (device
not active] or monitor module (Normal, Alarm, or Test).
Type Code The software Type Code that identifies the type of module. (Refer to “Point
Programming” in the NFS-320 Programming Manual.)
CBE list Only the first zone in the device’s CBE list will be displayed.
Device SLC Address The SLC address of the module.
Switch Inhibit (control/relay module only) Displays whether the remote ON/OFF capability
of the device is inhibited. (I=on; *=off).
Silenceable (control/relay module only) A selection that specifies if the device can be
silenced during an alarm by pressing the signal silence key. Possible values are:
* = output nonsilenceable
F = silenceable, resound by fire alarm
U = silenceable, resound by supervisory alarm
B = silenceable, resound by security alarm
T = silenceable, resound by trouble
O = silenceable, does not resound
Walk Test (control/relay module only) A selection that specifies if the device will activate
during a Walk Test.
How to View Read Status for a NAC
From the “Read Status” screen, press 0, then press the ENTER
key. You can now view Read Status for a NAC as follows:
press
OUTPUT, enter the device address, then press the ENTER
key. For example, to read the status of NAC 0-2: press
OUTPUT, enter 02, then press the ENTER key. The control
panel now displays information for a NAC as shown in
Figure 4.3.
The display and descriptions of the fields are shown below:
Figure 4.3 Sample NAC Read Status Display
Device Status The status of the device: ON (device active) OFF (device not active).
Type Code The software Type Code that identifies the type of NAC. Refer to “Appendix F -
Type Codes” in the NFS-320 Programming Manual.
CBE List Only the first zone in the NAC’s CBE list will be displayed here.
Device Address The address of the NAC (01-04)
Switch Inhibit A selection for disabling the switch function for the control/relay or
transponder output circuit. (I=on; *=off).
NOTE: If the “Strobe” Type ID is used with System Sensor Strobe synchronization, F, U, B, T, or
O will silence the entire circuit, “*” will silence the horn portion only.
Device address
next device
previous device
Type Code (CONTROL)
Walk Test selection:
W selected for Walk Test
* not selected
Label for the NAC
Default zone selection
Address (01-04)
B = NAC
Switch Inhibit: I selected, * not selected
Device status
Silenceable: O = selected, * = not selected (default)
OFF CONTROL FRONT HALLWAY NO. 2
Z000 *OW B02

Table of Contents

Other manuals for Notifier NFS-320

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Notifier NFS-320 and is the answer not in the manual?

Notifier NFS-320 Specifications

General IconGeneral
BrandNotifier
ModelNFS-320
CategoryControl Panel
LanguageEnglish

Related product manuals