1.3.5 Environmental conditions
(1)
Ambient temperature and relative humidity
Operating Non-operating
Storage
Unit
Temperature
Relative Humidity
41
to
104
14to
109.4
-40
to
158
(5 to 40)
(-lOto43)
(-40 to 70)
20 to 90
5to95 5to95
%
RH
The printer must be packed during storage
Avoid condensation at all times.
(2) Vibration
Operating
:
0.3G
(5 to 150 Hz) or less (except the unit is resonant frequency)
Non-operating :
1G
(5 to 150 Hz) or less (except the unit is resonant frequency)
(3)
Impact (Drop test)
Packing
:
30” (One corner and three edges and all six sides)
1.3.6 Noise
The
8-second
average noise is less than 57
dB(A)
(’
In
all mode), 52 dB(A) (in quiet mode) when
measured under the above conditions with the printer fitted with the acoustic cover.
1.3.7 Agency approvals
ULNo.
:
CSANo.
:
FCC
:
VDE
:
B5
:
The printer is listed in UL STANDARD No. 478.
CSA certification to CSA STANDARD C22.2 No. 220
FCC certified per Part 15, SUBJECT J, CLASS B.
VDE 0806.
VDE 0871 Class B.
ES
5850
I-7