Olympus AFU-100 EN Instructions for Use
WB135745-W10
35
The field strength from fixed transmitters, such as base stations from radio
(cellular / cordless) telephones and land mobile radios, amateur radio, AM and FM radio
broadcast and TV broadcast cannot be theoretical predicted with exact accuracy.
To assess the electromagnetic environment due to fixed high frequency transmitters, a
site survey should be considered. If the measured field strength at the location, where
the peristaltic pump unit is used, exceeds the above applicable compliance level, the
peristaltic pump unit should be observed to verify normal operation.
If unusual performance characteristics are observed, additional procedures may be
necessary, such as reorientation or relocating of the peristaltic pump unit.
Over the frequency range 150 kHz to 80 MHz, the field strength should be less than
3 V/m.
12.3 Recommended separation distances between portable
and mobile high frequency communication equipment and
the peristaltic pump unit
The peristaltic pump unit is intended for use in an electromagnetic environment where
the radiated high frequency disturbances are controlled. The user of the peristaltic pump
unit can help to prevent electromagnetic interference by maintaining a minimal distance
between portable and mobile high frequency communication equipment (transmitters)
and the peristaltic pump unit, according to the maximum output power of the
communication equipment, as recommended below.
Rated output
power of the
transmitter
Separation distance d according to frequency of the
transmitter in meter (m)
P in W 150 KHz … 80 MHz 80 … 800 MHz 800 MHz … 2.5 GHz
general 1.2 * Square root (P) 1.2 * Square root (P)
2.3 * Square root (P)
0.01 0.1 m 0.1 m 0.2 m
0.1 0.4 m 0.4 m 0.7 m
1 1.2 m 1.2 m 2.3 m
10 3.7 m 3.7 m 7.4 m
100 11.7 m 11.7 m 23.3 m
For transmitters rated at a maximum output power not listed above, the recommended
separation distance d in meters (m) can be determined using the equation applicable to
the frequency of the transmitter, where P is the maximum output power rating of the
transmitter in watts (W) according to the transmitter manufacturer.
NOTE
This guideline may not apply in all situations. Electromagnetic
propagation is affected by absorption and reflection from structures,
objects and people.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Olympus AFU-100 and is the answer not in the manual?

Olympus AFU-100 Specifications

General IconGeneral
BrandOlympus
ModelAFU-100
CategoryWater Pump
LanguageEnglish

Related product manuals