OMNI-624/OMNI-624EU Installation and Setup Guide
5-8
MANUAL UNBYPASS
UNBYPASS removes an existing bypass from a currently bypassed zone. The procedure is the same as
four bypass.
KEYPAD TAMPER: Upon entry of 21 keystrokes in succession without entry of a valid
command, the system will initiate a keypad tamper. If programmed (Submode 1, Question 13,
Location 2), the tamper condition initiates a keypad lockout, in which keypad commands will
not be accepted for approximately 20 minutes. The condition is annunciated by a pulsing
sound from the keypad. In addition, a code can be programmed for transmission to the central
station (see Submode 2, Question 41, L1, L2).
User Code Programming
User codes can be entered or modified directly through the keypad. The system supports up to 32 user
codes (4 or 6 digits each) with the following applications:
USER
NUMBER APPLICATION
DEFAULT
CODE
01 Master User (see note 2) 1234
0219 Normal Users NULL
2030 Door Strike (see note 3) NULL
3132 Ambush (see note 4) NULL
NOTES:
1. Only the master users (authority levels 1 and 2) can program or modify other users.
2.
User number 1 (cannot be deleted).
Programs all user codes (01
32); cannot be deleted.
3.
User numbers 20
30 (Door Strike).
Will be the system "door strike" code if any trigger is defined
as a door strike trigger. If any of the output triggers are defined as door strike, then entry of this
user code will activate that trigger for a period that is defined in Submode 1, Question 66, Locations
1 and 2 (partition 1) or 3 and 4 (partition 2). In addition, there is an option to allow all user codes to
act as a door strike code. If this option is selected (Submode 1, Question 13, L1), then all users can
activate the door strike through the [#] + [5] + [7] command (See Quick Command Modes). If a
door strike (or access) trigger is not defined, then this user code can be utilized as a normal user
code.
4.
User numbers 31 and 32 (Duress; enabled in Submode 1, Question 13, L1)
Will activate a
system-wide Duress code if there is a Duress CS report code programmed into Submode 2, Question
37, L1, L2. If no CS code is defined in Question 37, then these user numbers will be normal user
codes. In this mode, an entry of the user number code will ARM or DISARM the system and
transmit the ambush code to the central station. Furthermore, if the CS transmission format
contains the user number, the user number will be transmitted. If a Duress transmission code has
been programmed and a user does not exist, it will not be possible to activate the Duress feature.
AUTHORITY LEVELS
Each user is assigned one of 4 authority levels, which determines the system functions that user can
perform.