Section 5. System Operation
5-11
Quick Command Modes
The end user can perform the following commands (if programmed):
COMMAND KEYSTROKES DESCRIPTION
Change partition
# 0 [code] [0, 1,
2, or 9]
Changes mapping of current keypad to the partition
specified. This mode displays the current armed state of both
partitions. Changing a keypads partition with this command
directly changes the keypad/partition assignment
programmed in Questions 44 and 45.
Entering a 0 arms all partitions and a 9 disarms all
partitions. The arm all partitions command (0) will only be
valid if zones in the system are in a ready state.
Quick Arming # 1 Will arm the system, if it is ready to arm. Submode 1,
Question 14, L4
Quick Forced Arming # 2 Will bypass all currently faulted zones and arm system.
Submode 1, Question 14, L4
Set Time # 3
Enter Hours, Minutes, Month, Day, and Year. This question
may require a user code with an authority level of 1, 2, or 3,
to set the clock based on Installer program. (Submode 1,
Question 16, L2)
Display Zone Directory
(LCD Keypad Only)
# 4 Displays all zones enabled. Always enabled.
Display Directory of
Quick Commands
(LCD Keypad Only)
# 50 Allows the user to view the different quick commands.
Display Time
(LCD Keypad Only)
# 51 Used to verify the real-time clock settings used for CS test,
auto-arm and logging events. Displays hour, minute, month,
day, and year. The time is displayed in either 24 hour or 12
hour format and the date may be displayed with day or month
first, based on programming options in Submode 1, Question
16, location 3.
Display auto-arm time
(if auto-arm optioned )
(LCD Keypad Only)
# 52 Displays hour and minute of auto-arm time.
View Event Log
(LCD Keypad Only)
# 53 This option is enabled for users in Submode 1, Question 17,
L1. If enabled, the event log may be seen for the system.
Additionally, the time and date display options are adhered
to. This means the time may be in 24 hour or 12 hour format,
and the date may have either the day or month displayed
first. When the log is viewed through the quick command,
the clear log function is blocked. Either the [STAY] or the [
]
key may be used to exit this mode. Pressing any other key
advances to the next valid entry.