EasyManuals Logo
Home>Omron>Temperature Controller>E5DC

Omron E5DC Communications Manual

Omron E5DC
224 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
9
Precautions for Safe Use
E5@C Digital Temperature Controllers Communications Manual (H175)
Do not bend the communications cables past their natural bending radius. Do not pull on the
communications cables.
For the E5DC, when you attach the Main Unit to the Terminal Unit, make sure that the hooks on the
Main Unit are securely inserted into the Terminal Unit.
Install the DIN Track vertically to the ground.
For the E5DC, always turn OFF the power supply before connecting the Main Unit to or
disconnecting the Main Unit from the Terminal Unit, and never touch nor apply shock to the terminals
or electronic components. When connecting or disconnecting the Main Unit, do not allow the
electronic components to touch the case.
Observe the following precautions when you remove the terminal block or pulling out (draw out) the
interior of the E5GC.
Always follow the instructions provided in the E5
@
C Digital Controllers User’s Manual (Cat. No.
H174).
Turn OFF the power supply before you start and never touch nor apply shock to the terminals or
electric components.
When you insert the interior body of the Digital Controller, do not allow the electronic components
to touch the case.
Check for any corrosion on the terminals.
When you insert the interior body into the rear case, confirm that the hooks on the top and bottom
are securely engaged with the case.
Observe the following precautions when wiring the E5@C-B.
Follow the procedures given in the E5
@
C Digital Temperature Controller User’s Manual (Cat. No.
H174).
Do not wire anything to the release holes.
Do not tilt or twist a flat-blade screwdriver while it is inserted into a release hole on the terminal
block. The terminal block may be damaged.
Insert a flat-blade screwdriver into the release holes at an angle.
The terminal block may be damaged if you insert the screwdriver straight in.
Do not allow the flat-blade screwdriver to fall out while it is inserted into a release hole.
Do not bend a wire past its natural bending radius or pull on it with excessive force. Doing so may
cause the wire to break.
Do not use crossover wiring except for the input power supply and communications.

Table of Contents

Other manuals for Omron E5DC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron E5DC and is the answer not in the manual?

Omron E5DC Specifications

General IconGeneral
BrandOmron
ModelE5DC
CategoryTemperature Controller
LanguageEnglish

Related product manuals