4-18
Example of an n. + 4 Digits Parameter Setting
PR02W
operation
Front panel
key operation
Display example Explanation
(Present setting)
(less than
1 s)
Digit No. 3 Digit No. 0
Set the digit No. to be operated using the Left Key (front
panel: DATA Key for less than 1 s) or Right Key. You
cannot use only the Up and Down Keys.
Saving the Changed Setting to Memory
The following operation is not necessary if you are only checking the settings.
PR02W
operation
Front panel
key operation
Display example Explanation
(1 s min.)
Press the DATA Key (front panel: DATA Key for 1 s min.)
to save the data to memory (the setting display will flash
for approximately 1 s).
(After approx. 1 s) After the display has finished flashing, it will return to
normal.
D Return to Parameter Number Display
PR02W
operation
Front panel
key operation
Display example Explanation
(1 s min.)
Press the DATA Key (front panel: DATA Key for 1 s min.)
to return to the parameter No. display.
4-4-2 Parameter Tables
Some parameters are enabled by turning OFF the Unit, then turning it ON again. (See the tables be-
low.) When changing these parameters, turn OFF the power (check that the power lamp is not lit), then
turn ON the power again.
The specific digit number of a parameter for which each digit number must be set separately is dis-
played in the table with “.0” added to the digit number. For example, Pn001.0 (i.e., digit No. 0 of param-
eter No. Pn001).
The default setting for parameters set using 5 digits are displayed in the table with the leftmost digits
not shown if they are 0 (e.g., if the default setting is 00080, 80 is entered in the table).
Do not set parameters or digit numbers shown as “Not used.”
Parameters marked with one asterisk are for the DeviceNet Option Unit. Do not change the settings of
these parameters unless a DeviceNet Option Unit is mounted.
Parameters marked with two asterisks are supported by Servo Drivers with software version “r.0037.”
Operation Chapter 4

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron R88D-WT and is the answer not in the manual?

Omron R88D-WT Specifications

General IconGeneral
BrandOmron
ModelR88D-WT
CategoryServo Drives
LanguageEnglish

Related product manuals