K3T@ Intelligent Signal Processor Protocol
The K3T@ Intelligent Signal Processor Protocol is used to make various settings or control remotely the Intelli-
gent Signal Processor connected to the Serial Communications Unit/Board via RS-232C or RS-422/485 cable.
Protocol Configuration
The configuration of the K3T@ Intelligent Signal Processor Protocol is shown as follows:
Sequence
No.
Communications
sequence name
Function Ladder interface Notes
Send word
allocation
Receive word
allocation
300 (012C) Reset (by unit number) Performs the same processing as
when an input is received on the
reset terminal.
Ye s N o
301 (012D) Reset (continuous units) Performs the same processing as
when an input is received on the
reset terminal.
Ye s N o
302 (012E) Write set value (by unit
number)
Writes the set value HH, H, L, or
LL.
Ye s N o 1
303 (012F) Write set value HH (con-
tinuous units)
Writes the set value HH. Yes No 1
304 (0130) Write set value H (contin-
uous units)
Writes the set value H. Yes No 1
305 (0131) Write set value L (contin-
uous units)
Writes the set value L. Yes No 1
306 (0132) Write set value LL (con-
tinuous units)
Writes the set value LL. Yes No 1
307 (0133) Write set value with bank
(by unit number)
Writes the set value to a bank
which is not in use (K3TR: HH to
LL, K3TC: O1 to O5).
Ye s N o 2
308 (0134) Write set value HH with
bank (continuous units)
Writes the set value HH to a bank
which is not in use.
Ye s N o 1
309 (0135) Write set value H with
bank (continuous units)
Writes the set value H to a bank
which is not in use.
Ye s N o 1
310 (0136) Write set value L with
bank (continuous units)
Writes the set value L to a bank
which is not in use.
Ye s N o 1
311 (0137) Write set value LL with
bank (continuous units)
Writes the set value LL to a bank
which is not in use.
Ye s N o 1
312 (0138) Write set value O5 with
bank (continuous units)
Writes the set value O5 to a bank
which is not in use.
Ye s N o 1
313 (0139) Write set value O4 with
bank (continuous units)
Writes the set value O4 to a bank
which is not in use.
Ye s N o 1
314 (013A) Write set value O3 with
bank (continuous units)
Writes the set value O3 to a bank
which is not in use.
Ye s N o 1
315 (013B) Write set value O2 with
bank (continuous units)
Writes the set value O2 to a bank
which is not in use.
Ye s N o 1
316 (013C) Write set value O1 with
bank (continuous units)
Writes the set value O1 to a bank
which is not in use.
Ye s N o 1
317 (013D) Read set value (by unit
number)
Reads the set value HH, H, L, or
LL.
Ye s Ye s 1
318 (013E) Read set value HH (con-
tinuous units)
Reads the set value HH. Yes Yes 1