119
Table Data Processing Instructions Section 3-15
STACK SIZE
READ
(CS1-H, CJ1-H,
or CJ1M only)
SNUM
@SNUM
638
Counts the amount of stack data (number of words) in the specified stack. Output
required
STACK DATA
READ
(CS1-H, CJ1-H,
or CJ1M only)
SREAD
@SREAD
639
Reads the data from the specified data element in the stack. The offset value
indicates the location of the desired data element (how many data elements
before the current pointer position).
Output
required
STACK DATA
OVERWRITE
(CS1-H, CJ1-H,
or CJ1M only)
SWRIT
@SWRIT
640
Writes the source data to the specified data element in the stack (overwriting the
existing data). The offset value indicates the location of the desired data element
(how many data elements before the current pointer position).
Output
required
STACK DATA
INSERT
(CS1-H, CJ1-H,
or CJ1M only)
SINS
@SINS
641
Inserts the source data at the specified location in the stack and shifts the rest of
the data in the stack downward. The offset value indicates the location of the
insertion point (how many data elements before the current pointer position).
Output
required
STACK DATA
DELETE
(CS1-H, CJ1-H,
or CJ1M only)
SDEL
@SDEL
642
Deletes the data element at the specified location in the stack and shifts the rest
of the data in the stack upward. The offset value indicates the location of the
deletion point (how many data elements before the current pointer position).
Output
required
Instruction
Mnemonic
Code
Symbol/Operand Function Location
Execution
condition
TB: First stack
address
D: Destination
word
SNUM(638)
TB
D
TB: First stack
address
C: Offset value
D: Destination
word
SREAD(639)
TB
C
D
TB: First stack
address
C: Offset value
S: Source data
SWRIT(640)
TB
C
S
TB: First stack
address
C: Offset value
S: Source data
SINS(641)
TB
C
S
TB: First stack
address
C: Offset value
D: Destination
word
SDEL(642)
TB
C
D

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC CS/CJ Series and is the answer not in the manual?

Omron SYSMAC CS/CJ Series Specifications

General IconGeneral
BrandOmron
ModelSYSMAC CS/CJ Series
CategoryController
LanguageEnglish

Related product manuals