137
Other Instructions Section 3-29
3-29 Other Instructions
Instruction
Mnemonic
Code
Symbol/Operand Function Location
Execution
condition
SET CARRY
STC
@STC
040
Sets the Carry Flag (CY). Output
Required
CLEAR CARRY
CLC
@CLC
041
Turns OFF the Carry Flag (CY). Output
Required
SELECT EM
BANK
EMBC
@EMBC
281
Changes the current EM bank. Output
Required
EXTEND MAXI-
MUM CYCLE
TIME
WDT
@WDT
094
Extends the maximum cycle time, but only for the cycle in which this instruction
is executed.
Output
Required
SAVE CONDI-
TION FLAGS
(CS1-H, CJ1-H,
or CJ1M only)
CCS
@CCS
282
Saves the status of the condition flags. Output
Required
LOAD CONDI-
TION FLAGS
(CS1-H, CJ1-H,
or CJ1M only)
CCL
@CCL
283
Reads the status of the condition flags that was saved. Output
Required
CONVERT
ADDRESS FROM
CV
(CS1-H, CJ1-H,
or CJ1M only)
FRMCV
@FRMCV
284
Converts a CV-series PLC memory address to its equivalent CS-series PLC
memory address.
Output
Required
CONVERT
ADDRESS TO CV
(CS1-H, CJ1-H,
or CJ1M only)
TOCV
@TOCV
285
Converts a CS-series PLC memory address to its equivalent CV-series PLC
memory address.
Output
Required
STC(040)
CLC(041)
N: EM bank
number
EMBC(281)
N
T: Timer setting
WDT(094)
T
CCS(282)
CCL(283)
S: Word contain-
ing CV-series
memory address
D: Destination
Index Register
FRMCV(284)
S
D
S: Index Register
containing CS-
series memory
address
D: Destination
word
TOCV(285)
S
D

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC CS/CJ Series and is the answer not in the manual?

Omron SYSMAC CS/CJ Series Specifications

General IconGeneral
BrandOmron
ModelSYSMAC CS/CJ Series
CategoryController
LanguageEnglish

Related product manuals