EasyManuals Logo
Home>Pentair>Water Pump>INTELLIPRO VS+SVRS

Pentair INTELLIPRO VS+SVRS User Manual

Pentair INTELLIPRO VS+SVRS
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #20 background imageLoading...
Page #20 background image
13
INTELLIFLO
®
VS+SVRS and INTELLIPRO
®
VS+SVRS Variable Speed Pump Installation and User’s Guide
Settings: SVRS Auto Restart
The SVRS Auto Restart means that after the IntelliFlo
®
VS+SVRS Pump shuts down due to blockage
alarm, it will restart automatically after two (2) minutes. The default setting is two (2) minutes. When
the setting is enabled it can be set from 30 seconds to ve (5) minutes or to “Manual Restart”. Manual
Restart does not disable this feature, it requires you to manually reset the pump after a blockage alert.
Check your local codes and ordinance before changing this feature.
IMPORTANT NOTE: If SVRS Auto Restart is enabled: After a SVRS alarm the pump will attempt to soft
prime after the amount of time set in the SVRS Restart Time. During the soft prime the pump starts at
the Minimum RPM setting of the pump and slowly ramps up to the desired speed setting. If it senses a
blockage it will shut off and soft prime again. It will do this ten (10) times before attempting a full prime at
which time the SVRS will be off and a blockage will go undetected.
IMPORTANT NOTE: Disabling this setting does not mean that the SVRS suction blockage feature is being
disabled. When this setting is Disabled” it means that when the pump shuts down for a blockage alarm it
will not automatically restart. The pump will have to be manually restarted by pressing the RESET button,
and the START/STOP button.
To access the SVRS Auto Restart menu:
1. Check that the green power LED is on.
2. Press the Menu button. “Settings” is displayed.
3. Press the Select button. “Pump Address” is displayed.
4. Use the Up or Down arrow button to scroll to “SVRS”.
5. Press the Select button. “Enabled Auto Restart” is displayed.
To Disable the setting, press the Select button to highlight “Enabled” and press the Down
arrow button to change the setting to “Disabled,” then press the Enter, and Escape button.
6. Press the Down arrow button to display “SVRS Restart Time.” This is the duration of time
that “SVRS Auto Restart” is set to.
7. Press the Select button to change the setting. The cursor will appear in the time column.
8. Press Up or Down arrow button to change the auto restart time from 30 seconds to 5
minutes.
9. Press the Enter button to save the setting. To cancel any changes, press the Escape button to
exit edit mode without saving.
10. Press the Escape button to exit.
The VS+ SVRS pump can be sensitive to air in the circulation system and cause it
to give a false SVRS alarm, a blockage alarm when there is no blockage present.
It is always recommended to bleed the air off of the lter when starting the pump.
Suction side air leaks in the system can contribute to false SVRS alarms.

Table of Contents