Power revision (status 1)
1. Environmental conditions
Verify that the equipment environment complies with the specifications. Verify that the humidity is
adequate.
2. Enclosure state
Check the enclosure is in good general state and no traces of corrosion or impacts are present.
Check the posts anchoring.
3. Remote access
Verify that the equipment can be accessed remotely. If it exists, verify the connection with a PC.
4. Display operation
Check if the operation of the display is correct: Check the good condition of the screen, cleanliness,
deterioration or signs of any damage (impacts or breakage). Verify that the touch screen works on
its entire surface. Check that the lighting is correct and verify the interaction with the menu is smooth.
5. Main temperatures within the range
Remotely, if it exists, check the main internal maximum temperatures after 30 minutes at full power /
high power. Record the values. If the values are higher than 115ºC for IGBT and higher than 50ºC
inside, check the equipment completely.
6. Ventilation system and absence of vibrations
Verify that there are no abnormal noises or oscillations in the ventilation system.
7. Charge connector operation
Check the condition of the hoses and charging connectors, check that they are in good condition and
have no impact, cut or other marks.
8. Charge test
It is recommended to perform a complete charge on an electric vehicle to verify that it is finished
correctly, and the communications are working fine.
If the charge test is performed, it is the customer´s responsibility to ensure the presence of an
electric vehicle to perform the charging procedure with each type of connector.
If the charge test is performed, the costs derived from it must be assumed by the customer.
9. Operation of the differential switch (optional)
If the optional differential switch has been requested, check the correct operation of it using the test
button enabled for this purpose on the differential itself. Open the unit without voltage, then energize
it without any load, carry out the test and finally close the door. May wear the PPE needed for this
task.