OPTIONAL COMMUNICATIONS INTERFACES
WIFI WIRELESS COMMUNICATIONS
This communications interface operates independently of the other communications interfaces and
may be used at the same time as them.
WiFi interface
Connector type: SMA female (install the supplied 2.4 GHz antenna on this connector).
PROFIBUS COMMUNICATIONS
This communications interface operates independently of the other communications interfaces and
may be used at the same time as them.
PROFIBUS interface
The PROFIBUS interface may be accessed through the “PROFI/EIP/DEV” connector.
Connector type: DB9 female (socket)
Pin
PROFIBUS
Comments
3
B
4
RTS
5
GND
6
+5V
8
A
S
Shield
Ensure that the cable shield is connected to this via the plug shield connection.
PROFIBUS LED indicator
i-BUS
LED status
Indication
Continuous green
Online
PROFIBUS communications
Continuous red
Communication error
Extinguished
No communication

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Proton InteliSENS PD30 and is the answer not in the manual?

Proton InteliSENS PD30 Specifications

General IconGeneral
BrandProton
ModelInteliSENS PD30
CategoryLaundry Accessories
LanguageEnglish

Related product manuals