OPTIONAL INTERFACES
±10 Vdc output of diameters or errors, user scalable
WiFi*
PROFIBUS, PROFINET or EtherNet/IP.
OPTIONAL FUNCTIONALITY
Proportional Integral feedback controller
Maximum, minimum, mean, standard deviation, C
p
, C
pk
Statistical Process Control automatic set point for PI feedback
controller (requires PI feedback controller option)
Fast Fourier Transform analysis for amplitude and frequency of
periodic diameter variations
Single Measurement Flaw Detection (Lump and Neck detection)