Proton Products InteliSENS PD30 Instruction Manual (Issue 1a)
OPTIONAL INTERFACES
3x Analogue outputs
±10 Vdc output of diameters or errors, user scalable
Communication interfaces
WiFi*
PROFIBUS, PROFINET or EtherNet/IP.
OPTIONAL FUNCTIONALITY
PI feedback controller
Proportional Integral feedback controller
Statistics
Maximum, minimum, mean, standard deviation, C
p
, C
pk
SPC
Statistical Process Control automatic set point for PI feedback
controller (requires PI feedback controller option)
FFT
Fast Fourier Transform analysis for amplitude and frequency of
periodic diameter variations
SMFD
Single Measurement Flaw Detection (Lump and Neck detection)