Wireless Functions
SITE OPTIONS?
CHANGE TIMERS?
Radio Sprvn Time
[02]
Radio Force Set
No [0]
Radio Jmmng Time
[030]
Set with Poll Fl
No [0]
Fob Unset Entry
No [0]
Radio Bell Sprvn
No [0]
Site Options
In the site options function there are 3 functions for the
Enforcer:
• Radio Force Set: If any radio device is in fault
(e.g. has failed supervision or the signal is
jammed) and if this option is enabled, the user can
force the Enforcer to set regardless.
[0] No [1] Yes
• Set With Polling Fault: This allows the Enforcer to
set even if a device has missed 20 minutes worth
of device polls.
[0] No [1] Yes
• Fob Unset Entry: If this function is enabled a
keyfob can only be used to unset the control panel
when the entry time is counting down.
[0] No [1] Yes
• Radio Bell Supervision: If this function is enabled,
the bell performs its own supervision and jamming
protection, and will alarm if either condition occurs
(this cannot be silenced by the panel). The alarm
will stop after the bell expiry time, when the
jamming stops or when a supervision message
has been received by the panel. If this function is
disabled, it will work the same way as an input.
No supervision or jamming will be detected by
the bell, but the Enforcer will still detect both
depending on the timers.
[0] No [1] Yes
Use
b
and
x
to scroll to:
Press
t
until:
Use [ ],
t
until
Use [ ],
t
until
Use [ ],
t
until
Press
t
Change Timers
In the change timers function there are 2 functions for
the wireless (radio) operation:
• Radio Supervision Time: This is the time window
before a supervision fault will be signalled. For
example: if the time is set for 2 hours, then any
device that doesn’t communicate with the Enforcer
within that period will cause a supervision fault.
[0-
99] hours (0=supervision faults ignored) NOTE: Must be
set to 2 hours or less to comply with EN50131.
• Radio Jamming Time: This is the time window
that monitors the signals of each wireless
device. If a signal is ‘blocked’ for longer that the
programmed time a fault will be displayed.
[0-
100] seconds (0=jamming faults ignored). NOTE: It is
not recommended to program less than 10 seconds.
Must be set to 100 seconds or less (but not to zero) to
comply with EN50131.
Use
b
and
x
to scroll to:
Press
t
until:
Use [ ],
t
until
Press
t

Other manuals for Pyronix Enforcer 32WE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix Enforcer 32WE and is the answer not in the manual?

Pyronix Enforcer 32WE Specifications

General IconGeneral
BrandPyronix
ModelEnforcer 32WE
CategorySecurity System
LanguageEnglish

Related product manuals