8.5 Detection Zones
Up to 8 programmable zones can be wired to the PCB as shown. All tamper circuits must be wired in series and returned
to the dedicated tamper.
8.6 Auxiliary and Tamper
The Sterling 10 has a dedicated tamper. All tamper circuits must be returned to this terminal and wired in series.
8.7 Personal Attack PA
The Sterling 10 has a dedicated PA. All PA circuits must be returned to this terminal and wired in series.
8.8 Push To Set
The Push to Set switch must be a normally open contact type switch.
8.9 Speaker
One speaker or a combination of speakers may be attached provided that the resulting resistance is greater than 16
ohms.